Receiver Assy Basic 55L, 76mmØ (clamp-on lids)
Available
Receiver Assy Basic
55L - 76mmØ
suitable for use with clamp-on lids (to be purchased seporately)
Includes 1 plain lid & 1 lid with 76mm single nozzle.
During day to day running of the equipment it is good practice to establish a routine, where daily checks occur before each milking and periodic weekly maintenance occurs at the same time on the same day each week.
PERIODIC CHECKS
Daily
- After each washing ensure that the receiver assembly is properly drained.
Regularly
- The condition of the rubberware should be checked
- Listen for abnormal air leakages, particularly at joins in the milk line.
Every three months
- Check that the milk receiver and sanitary trap are being properly cleaned.
- Check for air leakage at the receiver lids.
Annually
- Replace all rubber gaskets, seals and tubes on the milk pump, receiver and sanitary trap.
- Check non-return valve is in good working order.
When hosing down, care should be taken not to direct water at the external parts of the electrical components in the assembly (particularly the milk pump and control box).
If a fault occurs with the receiver assembly, check the mains fuses, the fuse in the control box and the non-return flap valve.