Air Injector Control Box, 12v
Requires a 3A 12V DC power supply
The control box can be mounted on the wall or any available section of pipeline - which ever is most convenient for easy, daily access.
Where two air injectors are installed, a small tap must be fitted between the Lectron TL and the air injector.
Air injectors require regular routine weekly maintenance. Every week;
- Check the diaphragm for damage and replace as necessary.
- Clean the filter (it can be removed and rinsed in clean water)
- Keep the check valve clean (this enables free movement of the ball inside)
IMPORTANT - ensure air injectors are cleaned during the wash cycle as milk may enter the body compartment.
ROLL CLIPS - Open roll clip on the wash line tube during washing to allow wash solution to run through the air injector body into the milkline. The check valve ensures that air and/or milk are not forced into the wash line tube.
With older wash systems, a small amount of water may be forced up and out through the air injector at the end of the wash (this occurs when the milk pump is turned on to drain the last of the wash solution in the receiver, because there is no vacuum present to keep the diaphragm down). If this happens regularly check the filter and diaphragm more often.
Code | Product | Price | Min. Quantity |
Status | Quantity | |
---|---|---|---|---|---|---|
614824 | 614824 PCB for Air Injector Control Box | Login to see prices | 0 | Available |